{"id":3186,"date":"2025-02-20T16:41:11","date_gmt":"2025-02-20T15:41:11","guid":{"rendered":"https:\/\/cieplowent.pl\/in-issue-2-2025\/"},"modified":"2025-05-24T10:39:41","modified_gmt":"2025-05-24T08:39:41","slug":"in-issue-2-2025","status":"publish","type":"post","link":"https:\/\/cieplowent.pl\/en\/in-issue-2-2025\/","title":{"rendered":"In issue 2\/2025"},"content":{"rendered":"\n<p>\u2794 <a href=\"https:\/\/www.sigma-not.pl\/publikacja-152781-energetyczna-analiza-por%C3%B3wnawcza-zastosowania-powietrznej,-gruntowej-i-hybrydowej-pompy-ciep%C5%82a-w-instalacji-grzewczej-cieplownictwo-ogrzewnictwo-wentylacja-2025-2.html\">ROBERT SEKRET: Energy comparative analysis of the use of an air, ground and hybrid heat pump in a heating system<\/a><\/p>\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p><em>DOI: 10.15199\/9.2025.2.1<\/em><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"dropdown\">\n  <span>Zobacz streszczenie <\/span><\/p>\n<div class=\"dropdown-content\">\n<p>S\u0142owa kluczowe:magazynowanie ciep\u0142a, ciep\u0142o przemiany fazowej (PCM),l\u00f3dpompa ciep\u0142a,ciep\u0142o odpadowe, ogrzewanie budynk\u00f3w<\/p>\n<p>Streszczenie:<br \/>\nW artykule przedstawiono efekt energetyczny integracji prototypowego akumulatora ciep\u0142a wykorzystuj\u0105cego ciep\u0142o przemiany fazowej woda-l\u00f3d jako dodatkowego hybrydowego niskotemperaturowego \u017ar\u00f3d\u0142a ciep\u0142a w powietrznej pompie ciep\u0142a (HSHP). Do \u0142adowania akumulatora ciep\u0142a wykorzystano ciep\u0142o odpadowe z wentylacji i \u015bciek\u00f3w szarych. Przeprowadzono analiz\u0119 por\u00f3wnawcz\u0105 systemu HSHP z dwoma klasycznymi rozwi\u0105zaniami \u2012 powietrzn\u0105 pomp\u0105 ciep\u0142a (ASHP) i gruntow\u0105 pomp\u0105 ciep\u0142a (GSHP). Wyniki wskaza\u0142y, \u017ce w systemie HSHP zapotrzebowanie na energi\u0119 elektryczn\u0105 by\u0142o o 21% i 11% ni\u017csze ni\u017c odpowiednio w systemach ASHP i GSHP. Dodatkow\u0105 zalet\u0105 opracowanego rozwi\u0105zania by\u0142o wykorzystanie 58% ciep\u0142a odpadowego z budynku, co stanowi\u0142o 34% pokrycia zapotrzebowania na ciep\u0142o.\n<\/p>\n<\/p><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<p>\u2794 <a href=\"https:\/\/www.sigma-not.pl\/publikacja-152782-analiza-por%C3%B3wnawcza-uk%C5%82ad%C3%B3w-poligeneracyjnych-zasilanych-biomasa-cieplownictwo-ogrzewnictwo-wentylacja-2025-2.html\">Andrzej Kacprzak: Comparative analysis of biomass-powered polygeneration systems<\/a><\/p>\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p><em>DOI: 10.15199\/9.2025.2.2<\/em><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"dropdown\">\n  <span>Zobacz streszczenie <\/span><\/p>\n<div class=\"dropdown-content\">\n<p>S\u0142owa kluczowe: biomasa,  poligeneracja, trigeneracjaenergia odnawialna,efektywno\u015b\u0107 energetyczna<\/p>\n<p>Streszczenie:<br \/>\nW artykule przedstawiono analiz\u0119 r\u00f3\u017cnych uk\u0142ad\u00f3w poligeneracyjnych zasilanych biomas\u0105 umo\u017cliwiaj\u0105cych jednoczesne wytwarzanie energii elektrycznej, ciep\u0142a, ch\u0142odu oraz paliw i chemikali\u00f3w. Opisano podstawowe elementy tych uk\u0142ad\u00f3w, takie jak modu\u0142y kogeneracyjne, czy ch\u0142odziarki absorpcyjne. Szczeg\u00f3ln\u0105 uwag\u0119 po\u015bwi\u0119cono wykorzystaniu biomasy jako odnawialnego \u017ar\u00f3d\u0142a energii, kt\u00f3r\u0105 po przetworzeniu (zgazowaniu lub fermentacji metanowej) na gaz syntezowy lub biogaz mo\u017cna wykorzysta\u0107 jako paliwo w uk\u0142adach poligeneracyjnych. Om\u00f3wiono przyk\u0142ady instalacji wykonanych w Polsce. W artykule podkre\u015blono potencja\u0142 poligeneracji w kontek\u015bcie zr\u00f3wnowa\u017conego rozwoju i transformacji energetycznej zgodnych z celami Unii Europejskiej dotycz\u0105cymi dekarbonizacji i efektywno\u015bci energetycznej.\n<\/p>\n<\/p><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<p>\u2794 <a href=\"https:\/\/www.sigma-not.pl\/publikacja-152783-wykorzystanie-biomasy-w-ciep%C5%82ownictwie-cieplownictwo-ogrzewnictwo-wentylacja-2025-2.html\">RAFA\u0141 RAJCZYK: Use of biomass in the heating industry<\/a><\/p>\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p><em>DOI: 10.15199\/9.2025.2.3<\/em><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"dropdown\">\n  <span>Zobacz streszczenie <\/span><\/p>\n<div class=\"dropdown-content\">\n<p>S\u0142owa kluczowe: biomasa sta\u0142a, spalanie, biogaz biometan, ciep\u0142ownictwo, transformacja energetyczna<\/p>\n<p>Streszczenie:<br \/>\nW artykule dokonano przegl\u0105du obecnie stosowanych, jak i przysz\u0142o\u015bciowych metod wykorzystania biomasy sta\u0142ej w sektorze ciep\u0142owniczym. W cz\u0119\u015bci pierwszej przedstawiono statystyki dotycz\u0105ce wykorzystania paliw w sektorze ciep\u0142owniczym, ze szczeg\u00f3lnym uwzgl\u0119dnieniem biomasy, jak r\u00f3wnie\u017c przybli\u017cono czynniki mog\u0105ce wp\u0142yn\u0105\u0107 na poda\u017c biomasy w najbli\u017cszych latach, takie jak przewidziane na 2025 rok wdro\u017cenie Rozporz\u0105dzenia EUDR zwi\u0105zanego z przeciwdzia\u0142aniem wylesianiu i degradacj\u0105 las\u00f3w. Nast\u0119pnie opisano proces spalania i wsp\u00f3\u0142spalania biomasy w ciep\u0142ownictwie, wykorzystuj\u0105cy jako paliwo przede wszystkim zr\u0119bki, w aspekcie mo\u017cliwo\u015bci zast\u0105pienia ich biomas\u0105 pochodzenia rolniczego (peletem ze s\u0142omy). W dalszej cz\u0119\u015bci artyku\u0142u scharakteryzowano w skr\u00f3cie technologie oparte na wykorzystaniu biomasy i cechuj\u0105ce si\u0119 potencja\u0142em do zastosowania w ciep\u0142ownictwie, takie jak: wytwarzanie biogazu, zgazowanie biomasy, wytwarzanie biometanu z biomasy jak i spalanie w p\u0119tli chemicznej.\n<\/p>\n<\/p><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<p>\u2794 <a href=\"https:\/\/www.sigma-not.pl\/publikacja-152784-ch%C5%82odzenie-obiekt%C3%B3w-szpitalnych-z-wykorzystaniem-odnawialnych-%C5%BAr%C3%B3de%C5%82-energii-cieplownictwo-ogrzewnictwo-wentylacja-2025-2.html\">MICHA\u0141 WICHLI\u0143SKI, HUBERT PA\u0143KA: Cooling of hospital facilities using renewable energy sources<\/a><\/p>\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p><em>DOI: 10.15199\/9.2025.2.4<\/em><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"dropdown\">\n  <span>Zobacz streszczenie <\/span><\/p>\n<div class=\"dropdown-content\">\n<p>S\u0142owa kluczowe: obiekt szpitalny, produkcja ch\u0142odu, wsp\u00f3\u0142czynnik efektywno\u015bci COP<\/p>\n<p>Streszczenie:<br \/>\nW artykule wykonano analiz\u0119 efektywno\u015bci istniej\u0105cego centralnego systemu ch\u0142odzenia zw. \u0179r\u00f3d\u0142em ciep\u0142a i ch\u0142odu\u201d zainstalowanego w Samodzielnym Publicznym Wojew\u00f3dzkim Szpitalu Zespolonym w Szczecinie. Zosta\u0142a tak\u017ce rozwa\u017cona mo\u017cliwo\u015b\u0107 modernizacji systemu ch\u0142odzenia, kt\u00f3rej celem jest maksymalizacja stopnia wykorzystania odnawialnego \u017ar\u00f3d\u0142a energii (gruntowego wymiennika ciep\u0142a) i w efekcie obni\u017cenie kosztu ekologicznego i ekonomicznego eksploatacji instalacji ch\u0142odzenia obiektu szpitalnego. Modernizacja systemu polega na dodaniu miejscowych \u017ar\u00f3de\u0142 ch\u0142odu do zasilania niekt\u00f3rych odbior\u00f3w oraz przebudowie odbior\u00f3w w celu maksymalizacji wykorzystania ch\u0142odzenia \u201epasywnego\u201d (odbioru ciep\u0142a przez dolne \u017ar\u00f3d\u0142o ciep\u0142a- grunt). W rezultacie zaproponowanej modernizacji efektywno\u015b\u0107 energetyczna uk\u0142adu (COP) osi\u0105gnie warto\u015b\u0107 3,79, a jego udzia\u0142 ch\u0142odzenia pasywnego w og\u00f3lnej produkcji ch\u0142odu wyniesie 0,44. Natomiast efektywno\u015b\u0107 energetyczna analizowanego wariantu z uwzgl\u0119dnieniem wsp\u00f3\u0142pracy ze \u017ar\u00f3d\u0142em pasywnego ch\u0142odu wyniesie COP=9,1.\n<\/p>\n<\/p><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<p>\u2794 <a href=\"https:\/\/www.sigma-not.pl\/publikacja-152785-analiza-koncepcji-uk%C5%82adu-poligeneracyjnego-z-silnikiem-t%C5%82okowym-na-gaz-koksowniczy-cieplownictwo-ogrzewnictwo-wentylacja-2025-2.html\">MARCIN PANOWSKI, DAMIAN RADZIKOWSKI: Analysis of the concept of a polygeneration system with a piston engine for coke oven gas<\/a><\/p>\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p><em>DOI: 10.15199\/9.2025.2.5<\/em><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"dropdown\">\n  <span>Zobacz streszczenie <\/span><\/p>\n<div class=\"dropdown-content\">\n<p>S\u0142owa kluczowe: poligeneracja, gaz koksowniczy, silnik t\u0142okowym ch\u0142odziarka absorpcyjna<\/p>\n<p>Streszczenie:<br \/>\nW wielu procesach technologicznych wyst\u0119puje energia odpadowa najcz\u0119\u015bciej w postaci ciep\u0142a, w szczeg\u00f3lno\u015bci o niskiej temperaturze. Natomiast w koksowni w procesie produkcji koksu energia odpadowa wyst\u0119puje w postaci gazu koksowniczego, kt\u00f3ry mo\u017ce by\u0107 wykorzystany do pokrycia zapotrzebowania zak\u0142adu na r\u00f3\u017cne no\u015bniki energii, a w szczeg\u00f3lno\u015bci na ch\u0142\u00f3d w systemach HVAC. W artykule przedstawiono koncepcj\u0119 wykorzystania odpadowego gazu koksowniczego do pokrycia zapotrzebowania zak\u0142adu koksowniczego na ciep\u0142o do przygotowania c.w.u., centralnego ogrzewania obiektu, par\u0119 technologiczn\u0105, energi\u0119 elektryczn\u0105 oraz ch\u0142\u00f3d, przy czym do wytwarzania ch\u0142odu zaproponowano zastosowanie w uk\u0142adzie poligeneracyjnym absorpcyjnego agregatu wody lodowej. Analizy przeprowadzone na podstawie wynik\u00f3w oblicze\u0144 numerycznych wykonanych z wykorzystaniem opracowanego symulacyjnego modelu uk\u0142adu poligeneracyjnego wykaza\u0142y, \u017ce niezale\u017cnie od wielko\u015bci g\u0142\u00f3wnej produkcji zak\u0142adu, tj. produkcji koksu, uk\u0142ad poligeneracyjny mo\u017ce pokry\u0107 zapotrzebowanie zak\u0142adu na wszystkie niezb\u0119dne media. Ponadto, agregaty kogeneracyjne z gazowymi silnikami t\u0142okowymi wytwarzaj\u0105 wi\u0119cej energii elektrycznej ni\u017c wynosi zapotrzebowanie zak\u0142adu koksowniczego, a zatem sprzeda\u017c nadmiaru energii elektrycznej mo\u017ce stanowi\u0107 dodatkowe \u017ar\u00f3d\u0142o przychodu koksowni.\n<\/p>\n<\/p><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div style=\"height:70px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<p>\u2794 <a href=\"https:\/\/www.sigma-not.pl\/publikacja-152786-analiza-efektywno%C5%9Bci-paneli-fotowoltaicznych-ch%C5%82odzonych-ciecza-cieplownictwo-ogrzewnictwo-wentylacja-2025-2.html\">MARCIN PANOWSKI, KRZYSZTOF NOWAK: Efficiency analysis of liquid-cooled photovoltaic panels<\/a><\/p>\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p><em>DOI: 10.15199\/9.2025.2.6<\/em><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"dropdown\">\n  <span>Zobacz streszczenie <\/span><\/p>\n<div class=\"dropdown-content\">\n<p>S\u0142owa kluczowe: fotowoltaika, efektywno\u015b\u0107, odnawialne \u017ar\u00f3d\u0142a energii, ch\u0142odzenie paneli PV<\/p>\n<p>Streszczenie:<br \/>\nCh\u0142odzenie powierzchni roboczej paneli PV jest kluczowym czynnikiem operacyjnym, kt\u00f3ry pozwala osi\u0105gn\u0105\u0107 wy\u017csz\u0105 sprawno\u015b\u0107 w warunkach eksploatacyjnych. Panele w warunkach rzeczywistych nagrzewaj\u0105 si\u0119 nawet do temperatury przekraczaj\u0105cej 60\u00b0C, co powoduje znaczny spadek zar\u00f3wno sprawno\u015bci, jak i osi\u0105ganej mocy. Prawid\u0142owe ch\u0142odzenie mo\u017ce nie tylko poprawi\u0107 wydajno\u015b\u0107 elektryczn\u0105, ale tak\u017ce zmniejszy\u0107 szybko\u015b\u0107 degradacji ogniw, co skutkuje maksymalizacj\u0105 \u017cywotno\u015bci modu\u0142\u00f3w fotowoltaicznych i wi\u0119kszym uzyskiem energii. W pracy przedstawiono wyniki eksperymentalnych bada\u0144 paneli s\u0142onecznych ch\u0142odzonych wod\u0105, poprzez rozprowadzenie filmu wodnego na ich powierzchni. Uzyskane rezultaty wykaza\u0142y, \u017ce dzi\u0119ki ch\u0142odzeniu paneli mo\u017cna istotnie zwi\u0119kszy\u0107 uzysk energii przez popraw\u0119 sprawno\u015bci, a tak\u017ce, \u017ce grubo\u015b\u0107 filmu wodnego (w badanym zakresie) nie wp\u0142ywa w \u017caden spos\u00f3b, w tym negatywnie, na popraw\u0119 sprawno\u015bci.\n<\/p>\n<\/p><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div style=\"height:70px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<p><\/p>\n\n<h2 class=\"wp-block-heading has-black-color has-text-color has-link-color wp-elements-8638d5dace0896319417d8836a9548d5\"><strong>Z PRAKTYKI<\/strong><\/h2>\n\n<p class=\"has-black-color has-text-color has-link-color wp-elements-35b6a3f1460f6f09cdc87fa40c27102d\">\u2794 Magdalenia Biniek: Thermo-modernization and RES &#8211; key elements on the road to decarbonizing construction.  <strong><a href=\"https:\/\/cieplowent.pl\/wp-content\/uploads\/2025\/02\/Termomodernizacja-i-OZE-.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">FREE ACCESS<\/a><\/strong><\/p>\n\n<h2 class=\"wp-block-heading has-black-color has-text-color has-link-color wp-elements-1a3008480fb56c55974029ea47dead60\"><strong><strong>FROM THE LIFE OF UNIVERSITIES<\/strong><\/strong><\/h2>\n\n<div style=\"height:63px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<p class=\"has-black-color has-text-color has-link-color wp-elements-14b3c66d0c2e70eca614819b6c7bc271\">\u2794 <a href=\"https:\/\/www.sigma-not.pl\/publikacja-152788-badania-energetycznego-wykorzystania-biomasy-w-nowatorskich-reaktorach-clc-ze-spalaniem-w-p%C4%99tli-chemicznej-cieplownictwo-ogrzewnictwo-wentylacja-2025-2.html\">Tomasz Czakiert: Research of biomass energy utilization in novel CLC reactors realizing chemical loop combustion<\/a>.<\/p>\n\n<div style=\"height:63px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h2 class=\"wp-block-heading has-black-color has-text-color has-link-color wp-elements-925d59af87d4e36a271facfda8e8fb91\"><strong>MEDIA SPONSORSHIP<\/strong><\/h2>\n\n<p class=\"has-black-color has-text-color has-link-color wp-elements-0c8a3dc357a5b67ba9b02c704be0afb8\">\u2794 We invite you to participate in the ninth edition of the prestigious competition Investment of the Year<\/p>\n\n<p class=\"has-black-color has-text-color has-link-color wp-elements-0b2750d04a44d9f7ccf749837dc91792\">\u2794 Become an engineer of the future! Take part in the Sustainable Environment Competition and win the PW Index!<\/p>\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u2794 ROBERT SEKRET: Energy comparative analysis of the use of an air, ground and hybrid heat pump in a heating system DOI: 10.15199\/9.2025.2.1 \u2794 Andrzej Kacprzak: Comparative analysis of biomass-powered polygeneration systems DOI: 10.15199\/9.2025.2.2 \u2794 RAFA\u0141 RAJCZYK: Use of biomass in the heating industry DOI: 10.15199\/9.2025.2.3 \u2794 MICHA\u0141 WICHLI\u0143SKI, HUBERT PA\u0143KA: Cooling of hospital facilities [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":2962,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[33],"tags":[],"class_list":["post-3186","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-archives"],"acf":[],"_links":{"self":[{"href":"https:\/\/cieplowent.pl\/en\/wp-json\/wp\/v2\/posts\/3186","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cieplowent.pl\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/cieplowent.pl\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/cieplowent.pl\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/cieplowent.pl\/en\/wp-json\/wp\/v2\/comments?post=3186"}],"version-history":[{"count":0,"href":"https:\/\/cieplowent.pl\/en\/wp-json\/wp\/v2\/posts\/3186\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cieplowent.pl\/en\/wp-json\/wp\/v2\/media\/2962"}],"wp:attachment":[{"href":"https:\/\/cieplowent.pl\/en\/wp-json\/wp\/v2\/media?parent=3186"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/cieplowent.pl\/en\/wp-json\/wp\/v2\/categories?post=3186"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/cieplowent.pl\/en\/wp-json\/wp\/v2\/tags?post=3186"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}